An American veteran owned manufacturing and distribution company
for relays, solenoids, buzzers, sockets, timers and related accessories.relays, solenoids, buzzers, timers, sockets & accessoriesrelays, solenoids, buzzers, timers, relay sockets, solenoid sockets, timer sockets |
| RELAYS | LT41 Series | | With Quick Connect Terminals |
| FEATURES |
- Quick Connect Terminals
- Up to 30 Amp Contact Ratings Available
- Application: Compressors for Package Air Conditioning and Heater Switching Controllers
U.P.S. Source Circuit Control , Etc.
|
| | CONTACT RATING | | Load Type |
1A, (SPDM) |
2A, (DPDM) |
| Rated Load (Resistive) |
30A/220VAC |
25A/220VAC |
| Max. Switching Current |
30A |
25A |
| Max. Switching Voltage |
277VAC |
277VAC |
| Max. Switching Capacity |
6600VAC |
5500VAC |
| COIL DATA (DC) | Rated Voltage (V) |
Rated Current ±10% at 25°C (mA) |
Coil Resistance ±10% at 25°C (ohms) |
Max Continuous Voltage at 25°C |
Pick Up voltage (Max) at 25°C |
Drop Out Voltage(Min) at 25°C |
Power Consumption at Rated Voltage |
3 6 12 24 48 110 200 |
638.0 319.0 160.0 80.0 40.0 17.4 9.5 |
4.7 18.8 75.0 300.0 1200.0 6300.0 21000.0 |
110% of Rated Voltage |
75% of Rated Voltage |
10% of Rated Voltage |
Approx. 1.92W |
| COIL DATA (AC) | Rated Voltage (V) |
Rated Current ±10% at 25°C (mA) |
Max Continuous Voltage at 25°C |
Pick Up voltage (Max) at 25°C |
Drop Out Voltage(Min) at 25°C |
Power Consumption at Rated Voltage |
6 12 24 48 120 240 |
275 138 74 39 22.1 10.8 |
110% of Rated Voltage |
80% of Rated Voltage |
10% of Rated Voltage |
Approx. 1.7VA~2.7VA |
| SPECIFICATIONS | | Contact Resistance | 100m Ω Max. (Initial Value) |
| Operate Time | 30 ms Max. |
| Release Time | 30 ms Max. |
| Insulation Resistance | 1000 M Ω Min. (DC 500 V) |
| Dielectric Strength |
Between Open Contact: 4000 VAC, 50/60 Hz 1 Minute |
| Between Contact and Coil: 2000 VAC, 50/60 Hz 1 Minute |
| Between Live Parts and Ground: 2000 VAC, 50/60 Hz 1 Minute |
| Vibration Resistance | Damage Limits & Operating Extremes: 10~55 Hz, Amplitude 1.5mm |
| Shock Resistance | Damage Limits: 100G, Operating Extremes: 10G |
| Life Expectancy for Mechanical | 10,000,000 Operations (Frequency 18,000 Operations/Hour) |
| Life Expectancy for Electrical | 100,000 Operations (Frequency 360 Operations/Hour) |
| Operating Temperature | -40°C ~ +60°C (No Freezing) |
| Weight | Approx. 83g |
| ORDERING INFORMATION EXAMPLE: |
LT41
 |
SD
 |
1A
 |
120VAC
 |
| Series |
Options
| D | Snap Cover |
| S | Sealed Type |
| Q | Quick Terminal |
| P | PCB Terminal |
| H | High Insulation Type (Enlarge Contact Spacing)
|
|
Contact Form
| 1A | SPDM (Single Pole double Make) |
| 2A | DPDM (D0uble Pole Double Make)
|
|
Coil voltage
| |
|
|
| |
LINE ELECTRIC COMPANY
An American veteran owned manufacturing and distribution company
for relays, solenoids, buzzers, sockets, timers and related accessories. |
P.O. Box 127
S. Glastonbury, CT 06073 |
Tel: 860-659-3573
Fax: 860-659-3576
|
|
info@lineelectric.com
|