| RELAYS | MKH Series | | Industry Standard Octal Type Plug In |
| FEATURES |
- Industry Standard Octal Type Plug In for Quick Disconnect
- Contact Arrangements from 1 Form A to 3 Form C
- Indicator Lamp and Push-to-test Button available
- Use Sockets ORB8PF, ORB11PF and ORA11PF
|
| | CONTACT RATING | | Resistive Load | 10A/28VDC, 10A/120VAC, 5A240VAC |
| Motor | 1/6 HP 120VAC, 1/3 HP 240VAC |
| COIL DATA (DC) | Rated Voltage (V) |
Rated Current ±10% at 25°C (mA) |
Coil Resistance ±10% at 25°C (ohms) |
Max Continuous Voltage at 25°C |
Pick Up voltage (Max) at 25°C |
Drop Out Voltage(Min) at 25°C |
Power Consumption at Rated Voltage |
6 12 24 48 110 |
188 100 51 27 11 |
32 120 472 1800 10000 |
110% of Rated Voltage |
75% of Rated Voltage |
10% of Rated Voltage |
Approx. 1.2W |
| COIL DATA (AC) | Rated Voltage (VAC) |
Coil Resistance ±10% at 25°C (ohms) |
Max Continuous Voltage at 25°C |
Pick Up voltage (Max) at 25°C |
Drop Out Voltage(Min) at 25°C |
Power Consumption at Rated Voltage |
6 12 24 48 120 240 |
6 21 85 350 2,250 9,110 |
110% of Rated Voltage |
85% of Rated Voltage |
30% of Rated Voltage |
Approx. 2.0VA |
| SPECIFICATIONS | | Contact Resistance | 50m Ω Max. (Initial Value) |
| Operate Time | 20 ms Max. |
| Release Time | 10 ms Max. |
| Insulation Resistance | 1000 M Ω Min. (DC 500 V) |
| Dielectric Strength |
Between Open Contact: 500 VAC, 50/60 Hz 1 Minute |
| Between Contact and Coil 1500 VAC, 50/60 Hz 1 Minute |
| Between Contact Circuits 1500 VAC, 50/60 Hz 1 Minute |
| Vibration Resistance | Damage Limits & Operating Extremes: 10~55 Hz, Amplitude 1.5mm |
| Shock Resistance | Damage Limits: 100G, Operating Extremes: 10G |
| Life Expectancy for Mechanical | 10,000,000 Operations (Frequency 18,000 Operations/Hour) |
| Life Expectancy for Electrical | 100,000 Operations (Frequency 1,200 Operations/Hour) |
| Operating Temperature | -45°C ~ +70°C (No Freezing) |
| Weight | Approx. 79.2g |
| ORDERING INFORMATION EXAMPLE: |
MKH
 |
LM
 |
2C
 |
120VAC
 |
| Series |
Options
| L | Indicator Lamp |
| M | Push-to-Test Button
|
|
Contact Form
| 1C | 1 Form C |
| 2C | 2 Form C |
| 3C | 3 Form C |
| 4A | 4 Pole STNO |
|
Coil Voltage
| |
|
|
| |
LINE ELECTRIC COMPANY
An American veteran owned manufacturing and distribution company
for relays, solenoids, buzzers, sockets, timers and related accessories. |
P.O. Box 127
S. Glastonbury, CT 06073 |
Tel: 860-659-3573
Fax: 860-659-3576
|
|
info@lineelectric.com
|
| © 2004 Line Electric Company, All rights reserved. |